On Sun, 2005-03-27 at 12:33, Jim Adney wrote:
> On 26 Mar 2005 at 0:31, Dave Hall wrote:
> 
> > > DUHHHHH, Just sitting here thinking about it. Connect the coil of the
> > > isolator relay to the D+ of the generator. There is no voltage there
> > > until the engine starts and the generator is above it's cut in speed.
> > > 12V Gen. cut-in = 2200-2300 armature RPM = 1000 RPM crankshaft. approx.
> 
> > Russ, what's wrong with using the charging light output connection on the VR to
> > operate the relay for the second battery? 
> 
> Nothing. Those 2 terminals are connected together inside the VR. They are 
> electrically identical.

I have never payed that close of attention to the internals in a
regulator.
But now that you mention it, the schematic on the outside of a Bosch
regulator box does show it a D+/61.

-- 
Russ Wolfe
'71 FB AT
'66 FB MT
'64 T34 (not running)
'65 T1 (not running)
'05 KIA Sorento SUV