<x-flowed> On Mar 4, 2005, at 2:15 PM, Jim Adney wrote:
Could the old generator being bad have been such a load that the engine
had to work harder?
I suppose it's possible. Measure the resistance between D+ and DF on your bad
generator. It should be 3.5-4.0 Ohms. As a test, you could compare with the
good generator. The only thing I can think of is that you had some badly
shorted field windings and that was causing you all these problems. Shorted
field windings could happen if they overheated, and you already told us that
this thing looks like it got hot at some time.
I'm still curious about this possibility.
--fess