[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [T3] Can't get the point gap right
On Saturday 11 August 2001 15:11, Mark Healey wrote:
> After puting in the new FI parts and them all seeming to work so far I
> am trying to ajust everything to stock specs. The only problem is
> that I can't get the dwell right. On my 8 cyl meter it always reads
> about 20 degrees. According to muir closing the points increases the
> dwell. Using my feeler guages I went as low as .010 and it still
> reads 20.
>
> The points and condenser are new.
>
If you are using a 8 cyl. dwell meter, just set them to .016" with a feeler
gage and go for it. There may be a problem with your dwell meter, using it on
a 4 cyl.
What does the dwell meter show when it is not connected. It should read zero.
--
Russ Wolfe
russw@classicvw.org
http://www.classicvw.org
-------------------------------------------------------------------
List info at http://www.vwtype3.org/list or mailto:help@vwtype3.org