Re: [T3] AB dizzy timing


On Sun, 2003-04-20 at 22:03, Greg Merritt wrote:


> 
> 	If their 30degree tolerance is rock-solid, then I'm going to 
> to *advance* it a couple of degrees up to zero tdc @ static, so that 
> the max advance is 27-30.  (Now, given that the total advance could 
> only be 30 net degrees, then I've got it set to (27-30) minus two, or 
> like 25-28 or so.
> 
> 	Or something... :-o
> 
> 	I'll need to get some better measurements of the pulley and 
> figure out the 30 degree spot for myself.
> 
One thing to remember, is that the T-1 crank pulley is a different
diameter than the T-3 pulley. I think those dimensions that were given
in a previous post were for the T-3 pulley.

-- 
Russ Wolfe
'66 FB MT
'71 FB AT 