[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]

Re: [T3] strange electrical problems


On 19 Apr 2003 at 9:36, Garret Trask wrote:

> From Russ Wolfe:
> 
> >That wire should go to the fuse box. My Bently shows it going to the 4th
> >fuse from the right. This fuse is hot with the key "ON".

That's where Bentley shows it 68-70, but they moved it to the far right fuse 
for 71-3. Note that in both cases it is actually connected to the UNFUSED side 
of the fuse.

> Ok, so that one is hot, that means the rest must just be ground, right?  But the
> one that connects to the turn signal is hot.  Does this mean my turn signal
> flasher is bad?

I'm not sure. The TS indicator lamps DO get their power from this black wire, 
so the TS relay should give the other side of these bulbs an intermittent 
ground to turn them on. It's possible that your TS relay is just miswired.


-- 
*******************************
Jim Adney, jadney@vwtype3.org
Madison, Wisconsin, USA
*******************************

-------------------------------------------------------------------
List info at http://www.vwtype3.org/list | mailto:gregm@vwtype3.org


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]