[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]

RE: [T3] Dead Injectors Puzzler


On 10 Jan 2001, at 13:02, Fuhriman, Mark wrote:

> This is sounding like the description Steve offered a few messages before,
> with the gap on one side being larger than the other..  But rather than bend
> those arm springs that hold the contacts, I think I'd rather just replace
> with a good set.

Yes, Steve's description sounded exactly like mine. I tried bending 
the fixed contact, too, and I managed to make it seem to work 
okay, but by the time I got it bent far enough to give the same dwell 
it was so far out of alignment (sort of hitting on the edge/side of the 
contact) that I was worried that it wouldn't be reliable. I didn't like 
the fact that the bent contact might tend to push the moving 
contact sideways.

How bad was yours bent, Steve, and how long has it been running 
since you fixed it?

Mine left me puzzled because I could never find anything about it 
that seemed worn or malformed. It seemed as if it had just been 
made wrong from the start, but it was definitely different from all the 
others that I had.

-
Jim Adney
jadney@vwtype3.org
Madison, WI 53711-3054
USA

-------------------------------------------------------------------
Unsubscribe? mailto:type3-request@vwtype3.org, Subject: unsubscribe