[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
RE: [T3] generator issues continue...
First off, your rebuilt online one is more than likely going to have its own
problems...
The field windings can have insulation that wears thru and grounds against
the screws that hold the whole thing together, so make sure there is good
insulation on them and that their connections to the posts is good. Check
to make sure the screw that holds the rear cover electrical connection on it
tight, it's the only screw youll see as you look in the brush end
lengthwise.
Get the right brushes, they are $2 and available anywhere... they should
slide up and down freely and yea, some of the rustier springs may need a
little help with a little block between them and the brush but in general
this isn't necessary until the brushes have worn down.
Keith
> service, and not having to take the generator in and out three times.
> Hopefully he can figure out what he is going wrong today, or I may try to
> ask to get my money back, and order a newly rebuilt one online.
>
> A few posts have mentioned a small screw on the front end of the
> generator.
> The only screws I see are the following
> -two large head screws on either side of the generator
> -A small screw holding a ground wire in the middle of the generator.
> -a small screw holding down the black block with spade connectors.
> -small screws holding wires connecting to brushes
> -two screws that run through the whole generator holding it together.
>
>
> ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~