[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]

Re: [T3] red loctite for oil sump studs?


On 18 Dec 2005 at 22:59, BOB2TYPE3S@aol.com wrote:

> In a message dated 12/18/05 9:02:07 PM Eastern Standard Time, 
> jadney@vwtype3.org writes:
> 
> << Is a stripped 6mm hole small enough to do good 1/4-20 threads in? 
>  Seems like it might be a bit oversize already....
>  
>  Will a 1/4-20 stud pass thru the sump plate?
>  >>
> Yup, and yup. This is really a quick fix, but it works very well, and lasts a 
> long time. If you thing about it, a 1/4-20 is between a 6mm stud and a 7mm 
> stud.

I'm at work now, so I walked down to look at the tap drill chart. The correct 
tap drill for a 1/4-20 (75% thread in soft metals) is .201". A .219" hole would 
give you a 50% thread. The stripped out 6mm hole would be about .240", which is 
almost no smaller than the 1/4" stud you want to put in there.

Maybe this will work if you have a 6mm stud which is just loose, but it sounds 
pretty skimpy for a completely stripped out hole. 

Nevertheless, it's a reasonable thing to try if you only have the commonly 
available tools.

-- 
Jim Adney
jadney@vwtype3.org
Madison, WI 53711-3054
USA

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
List info at http://www.vwtype3.org/list | mailto:gregm@vwtype3.org
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]