[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]

Re: [T3] OT: Timing/dwell relationship and Pertronix


I always thought that the tit would keep changing the effective points gap
and therefore the timing so I stopped using them
Standard ignition sells the ventilated lubripoints, GB4173XP for the FI
distributors.
They last at least 15Kmi, when I just change them as part of the tuneup
anyway.  I dont think Bosch sells ventilated points.

Keith


 Ive NEVER worried about or set dwell at all!
> > I set the points gap carefully to spec, and since I use ventilated
> > points I
> > never get the "tit" on them and the gap stays consistant.
>
> Are those Bosch points? I always seem to get that tit on the points
> only after a thousand miles or so. I usually just ignore it and adjust
> them via a dwell meter.


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
List info at http://www.vwtype3.org/list | mailto:gregm@vwtype3.org