[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]

Re: [T3] Generator again


On 10 Feb 2004 at 15:23, Mike Wodkowski wrote:

> I should have mentioned a couple things:
> 
> A) my idle speed, timing and dwell are fine.
> 
> B) the generator light goes out when I'm in gear and moving down the street,
> once I get going in any given gear.

So, the gen light stays on at idle, but goes out once you're under way?

> C) Oddly, revving the engine in neutral has no effect.

You mean that the gen light stays on no matter how long you keep the revs up 
while standing still?

VERY strange. I'm wondering if you have multiple problems: one consisting of a 
chafed wire between the gen and the VR, and the other consisting of an 
overheated field coil due to the occasional short to ground of the DF wire.

Just a guess, but see what you can inspect where the wire runs.

-- 
*******************************
Jim Adney, jadney@vwtype3.org
Madison, Wisconsin, USA
*******************************

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
List info at http://www.vwtype3.org/list | mailto:gregm@vwtype3.org


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]