[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] [New Search]

Re: [T3] No start problems still


On 2 Aug 2002, at 6:26, incynr8 wrote:

> Both relays check out, pump runs, have 2 gals of gas in tank. Injectors at 3
> ohms, injector points function. Temp sensor 1 at 1450 ohms, temp sensor 2 at
> 188. Injectors seem to get signals from wires, but not fire. I am trying more
> gas in tank, as my pressure gauge only reads to 15psi, and cleaning contacts
> for injectors to harness. Seems like they SHOULD fire. 

Any chance that the other side of the injectors arean't getting good grounds?

What year was this? 68-9 injector grounds were a problem area.

-
Jim Adney
jadney@vwtype3.org
Madison, WI 53711-3054
USA

------------------------------------------------
To unsubscribe, E-mail to: <type3-off@vwtype3.org>
For more help, see http://vwtype3.org/list/