--- Mark Healey <marksvw@healeyonline.com> wrote: > After puting in the new FI parts and them all > seeming to work so far I > am trying to ajust everything to stock specs. The > only problem is > that I can't get the dwell right. On my 8 cyl meter > it always reads > about 20 degrees. According to muir closing the > points increases the > dwell. Using my feeler guages I went as low as .010 > and it still > reads 20. > > The points and condenser are new. > Phil again I forget that some people have not been working on these type three's for forty years like I have .I forgot to tell you that the dwell should be set at 44 to 52 degrees that would be 22 to 26 on the 8 cyl scale > > > Mark Healey > 71 FI auto square > 71 FI manual square > marksvw@healeyonline.com > > > ------------------------------------------------------------------- > List info at http://www.vwtype3.org/list or > mailto:help@vwtype3.org > __________________________________________________ Do You Yahoo!? Send instant messages & get email alerts with Yahoo! Messenger. http://im.yahoo.com/