Re: [T3] Glowing Generator Light


On 27 May 99, at 21:27, Stan Schaefer wrote:

> In addition to Jim's suggestion, check the area around the bolts that
> hold the regulator down.  I had a similar problem at one time, it was
> due to the regulator sitting in a very rusty spot and not getting a
> good ground through the mounting screws.  A separate ground wire to a
> non-rusty area did the trick.

Stan is right. This is a very good thing to check. All cars since 69 
have a separate ground wire from the generator to the VR, but at the 
factory this wire was just attached to one of the VR hold-down 
screws. If you look at the VR you will see that there is actually a 
separate screw on the frame that will make a better ground. Move the 
wire to this screw. If the ground wire was not getting a good 
connection then this will help.

Jim
-
*******************************
Jim Adney, jadney@vwtype3.org
Madison, Wisconsin, USA
*******************************

-------------------------------------------------------------------
List info at http://www.vwtype3.org/list or mailto:help@vwtype3.org